Key Features
- HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- 45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
- Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
- Hot Swappable Controller: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
- Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
- RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
- Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
- RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
- Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
- Per-Inlet Power Sensing (PIPS®): Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- Per-Outlet Power Sensing (POPS®): Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses.
- Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
- Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
- High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60°C data center environments.
- Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
- Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
SMART PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 120/208V 3-PHASE 3
C4S36RA-YCBE2FE3/1500
SKU 15051770
Regular price saves you $370.04 against MSRP.
Contact us to check availability
Product Overview
SMART PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 120/208V 3-PHASE 3
- Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 1.5m custom cord length
- Server Technology PRO4X 39-Outlets PDU - Monitored - NEMA L21-30P - 12 x IEC 60320 C13, 24 x CX, 3 x NEMA 5-20R - 208 V AC - Branch Circuit, Circuit Protection, Fuse, Overload Protection, Double Pole - Network (RJ-45) - 4.92 ft Cord Length - Button Mount, Rack-mountable
- Server Technology PRO4X 39-Outlets PDU
- Monitored - NEMA L21-30P - 12 x IEC 60320 C13, 24 x CX, 3 x NEMA 5-20R - 208 V AC - Branch Circuit, Circuit Protection, Fuse, Overload Protection, Double Pole - Network (RJ-45) - 4.92 ft Cord Length - Button Mount, Rack-mountable
Technical Specifications
| Application/Usage | Data Center |
| Product Type | PDU |
| Input Voltage | 208 V AC |
| Manufacturer Part Number | C4S36RA-YCBE2FE3/1500 |
| Limited Warranty | 2 Year |
| Output Voltage | 120 V AC |
| Output Voltage | 208 V AC |
| Features | Multi-color LCD |
| Features | LED Status Indicator |
| Input Current | 30 A |
| Manufacturer | Legrand Group |
| Product Name | PRO4X 39-Outlets PDU |
| Mount Type | Button Mount |
| Mount Type | Rack-mountable |
| Protection Type | Branch Circuit |
| Protection Type | Circuit Protection |
| Protection Type | Fuse |
| Protection Type | Overload Protection |
| Protection Type | Double Pole |
| Product Series | PRO4X |
| Brand Name | Server Technology |
| Plug/Connector Type | NEMA L21-30P |
| Cord Length | 4.92 ft |
| Height | 70" |
| Width | 2.2" |
| Depth | 2.5" |
| Input Frequency | 60 Hz |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Type | CX |
| Receptacle Type | NEMA 5-20R |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Network (RJ-45) | Yes |
| Load Capacity (Watt) | 8600 W |
| UL Listed | Yes |
| PDU Type | Monitored |
| Product Color | Black |
| Color Family | Black |
| Locking Receptacles | RamLock Locking Outlet |
| Receptacle Detail | 12 x IEC 60320 C13 |
| Receptacle Detail | 24 x CX |
| Receptacle Detail | 3 x NEMA 5-20R |
Marketing Information
- PRO4X 39-Outlets PDU
- Standard Button Mounts
Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input, outlet and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.
- HTTP(S)
- SSH
- Telnet
- SNMP
- (S)FTP
- SMTP
- Syslog
- LDAP(S)
- RS-232 serial
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- SNMPv2c
- v3 (GET, SET, Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
Shipping & Dimensions
Similar Products
SMART PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 230V 1PH 63A (DE-R
C4S36RA-EQBE2FE2
MANAGED RACK PDU, 2U, 3PH, L21-30P INPUT, 15FT CORD, 120/208V, 24A, OUTLETS: (24
EMAU19-15
SMART POPS PRO4X IX9 PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208-240V 3-P
C4T36RA-DFBD2FE1/2000
SMART POPS PRO4X IX9 PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208-240V 3-P
C4T36RA-DFBD2FE1/20W2
SWITCHED EXPANSION PRO2 (48) CONFIGURABLE ALT PHASE HDOT OUTLETS, 415V 3PH WYE 6
C2X48TE-5PAE2M99
SMART POPS PRO4X IX9 PDU, 48 RAMLOCK HDOT OUTLETS (24 C13 + 24 CX), 230V 1PH 32A
C4T48RA-EPBE2ED7