Key Features

  • HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • 45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
  • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot Swappable Controller: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
  • RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
  • Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
  • RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental Monitoring: Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Per-Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Per-Outlet Power Sensing: POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
  • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
  • Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
SERVER TECHNOLOGY PDUs

SWITCHED POPS PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208V 20A (

Mfr # C4G36RA-2BBE2FE2 SKU 14874857

$3,432.66 MSRP $4,056.00 Save 15%

Regular price saves you $623.34 against MSRP.

Available

Contact us to check availability


Product Overview

SWITCHED POPS PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208V 20A (

  • SWITCHED POPS PRO4X IX PDU 208V 20A (16A RATED) NEMA L6-20P
  • Server Technology PRO4X 36-Outlets PDU - Switched - NEMA L6-20P - 12 x IEC 60320 C13, 24 x CX - 208 V AC - Branch Circuit, Circuit Protection, Fuse, Double Pole, Overload Protection - Network (RJ-45) - Button Mount, Rack-mountable
  • Server Technology PRO4X 36-Outlets PDU
  • Switched - NEMA L6-20P - 12 x IEC 60320 C13, 24 x CX - 208 V AC - Branch Circuit, Circuit Protection, Fuse, Double Pole, Overload Protection - Network (RJ-45) - Button Mount, Rack-mountable

Technical Specifications

Application/Usage Server
Application/Usage Data Center
Product Type PDU
Input Voltage 208 V AC
Manufacturer Part Number C4G36RA-2BBE2FE2
Limited Warranty 2 Year
Output Voltage 208 V AC
Features Multi-color LCD
Features LED Status Indicator
Input Current 20 A
Manufacturer Legrand Group
Product Name PRO4X 36-Outlets PDU
Mount Type Button Mount
Mount Type Rack-mountable
Protection Type Branch Circuit
Protection Type Circuit Protection
Protection Type Fuse
Protection Type Double Pole
Protection Type Overload Protection
Product Series PRO4X
Brand Name Server Technology
Plug/Connector Type NEMA L6-20P
Height 70"
Width 2.2"
Depth 2.5"
Input Frequency 60 Hz
Receptacle Type IEC 60320 C13
Receptacle Type CX
Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 140°F (60°C)
Minimum Storage Temperature -22°F (-30°C)
Maximum Storage Temperature 176°F (80°C)
Network (RJ-45) Yes
Load Capacity (Watt) 3300 W
UL Listed Yes
PDU Type Switched
Remote Outlet Switching Yes
Locking Receptacles RamLock Locking Outlet
Receptacle Detail 12 x IEC 60320 C13
Receptacle Detail 24 x CX

Marketing Information

  • PRO4X 36-Outlets PDU
  • Standard Button Mounts

Server Technology's PRO4X Switched POPS PDUs run on our state-of-the-art Xerus network interface platformand provide remote access to power, PDU status, input, outlet and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanismto prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched POPS PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions fromLegrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c and v3 (GET, SET, Traps)
  • IPv4 and IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP

Shipping & Dimensions

27
Weight (lbs)
79"
Length
9"
Width
7"
Height