Key Features
- Complete line isolation, noise filtering and surge suppression; ideal for sensitive equipment
- 250 watts, 2 outlets, 6-ft. power cord
- Hospital-grade plug and receptacles
- Leakage current less than 100 microamps
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
EATON TRIPP LITE SERIES ISOLATOR SERIES 120V 250W UL 60601-1 MEDICAL-GRADE ISOLA
IS250HG
SKU 2511286
UPC 037332116208
Regular price saves you $206.97 against MSRP.
Contact us to check availability
Minimum order quantity: 4
Product Overview
EATON TRIPP LITE SERIES ISOLATOR SERIES 120V 250W UL 60601-1 MEDICAL-GRADE ISOLA
- ISOLATOR250WATT/2OUT HOSP GRADE 6FT CORD/HG OUTLET/PLUG UL2601
- Eaton Tripp Lite Series Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets, TAA - 250W - 120V AC - 120V AC
- Eaton Tripp Lite Series Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets, TAA
- 250W - 120V AC - 120V AC
Technical Specifications
| Product Type | Isolation Transformer |
| Input Voltage | 120 V AC |
| Manufacturer Part Number | IS250HG |
| Limited Warranty | 2 Year |
| Output Voltage | 120 V AC |
| Form Factor | Tower |
| Manufacturer | Eaton Corporation |
| Product Model | IS250HG |
| Product Name | Isolator IS250HG Isolation Transformer |
| Power Rating | 250 VA |
| Brand Name | Tripp Lite series |
| Country of Origin | Taiwan |
| Height | 4.5" |
| Width | 4.8" |
| Depth | 7.8" |
| Maximum Line Current | 2.10 A |
| TAA Compliant | Yes |
| Output Receptacle Type | NEMA 5-15R |
Marketing Information
- IS250HG
- IS250HG Isolation Transformer
- Instruction manual with warranty information
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
Shipping & Dimensions
Similar Products
EATON 93PM UPS 480V IN, 208/120V OUT 40KW N+1; ALL COMM CARDS 3 STRINGS BATTS, 3
9AB204J129E20R0
EATON 93PM UPS 480V IN, 208/120V OUT 200KW; ALL COMMUNICATION CARDS, 3 BREAKER M
9AE420J029H20R0
EATON 93PM UPS 480V IN, 208/120V OUT; 50KW 5 STRINGS BATTS, 3 BREAKER MBS
9AA104J325H20R0
EATON 93PM UPS 480V IN, 208/120V OUT 30KW N+1; ALL COMM CARDS, 3 BREAKER MBS
9AC203J029H20R0
MANAGED RACK PDU, 2U, 3PH, L21-30P INPUT, 15FT CORD, 120/208V, 24A, OUTLETS: (24
EMAU19-15
COMPUTER POWER CORD, 360 ROTATING RIGHT ANGLED NEMA 5-15P TO C13 - HEAVY-DUTY, 1
P007-010-15RR