APC NETSHELTER RACK PDU ADVANCED, METERED OUTLET, 3PH, 17.3KW, 208V, 60A, 460P9,
APDU11452MO
SKU 14830062
Regular price saves you $2,836.04 against MSRP.
Contact us to check availability
Product Overview
APC NETSHELTER RACK PDU ADVANCED, METERED OUTLET, 3PH, 17.3KW, 208V, 60A, 460P9,
- Schneider Electric (APDU11452MO) PDUs
- APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 17.3kW, 208V 60A, 460P9, 42 Outlet - Metered-by-Outlet - IEC 60309 60A 3P+PE - 21 x IEC 60320 C13/C15/C19/C21, 21 x IEC 60320 C13/C15 - 208 V AC - Network (RJ-45) - 9.84 ft Cord Length - 0U - Vertical - Rack-mountable
- APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 17.3kW, 208V 60A, 460P9, 42 Outlet
- Metered-by-Outlet - IEC 60309 60A 3P+PE - 21 x IEC 60320 C13/C15/C19/C21, 21 x IEC 60320 C13/C15 - 208 V AC - Network (RJ-45) - 9.84 ft Cord Length - 0U - Vertical - Rack-mountable
Technical Specifications
| Application/Usage | IT Equipment |
| Application/Usage | Server |
| Application/Usage | Data Center |
| Product Type | PDU |
| Input Voltage | 208 V AC |
| Manufacturer Part Number | APDU11452MO |
| Packaged Quantity | 1 / Pack |
| Limited Warranty | 3 Year |
| Output Voltage | 208 V AC |
| Weight (Approximate) | 24.47 lb |
| Input Current | 60 A |
| Manufacturer | Schneider Electric SA |
| Product Name | NetShelter 42-Outlets PDU |
| Mount Type | Rack-mountable |
| Product Line | NetShelter |
| Rack Height | 0U |
| Brand Name | APC by Schneider Electric |
| Plug/Connector Type | IEC 60309 60A 3P+PE |
| Placement | Side |
| Cord Length | 9.84 ft |
| Height | 70.1" |
| Width | 2.2" |
| Depth | 3" |
| Input Frequency | 60 Hz |
| Phase | Three Phase |
| Receptacle Type | IEC 60320 C13/C15/C19/C21 |
| Receptacle Type | IEC 60320 C13/C15 |
| Minimum Operating Temperature | 23°F (-5°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -13°F (-25°C) |
| Maximum Storage Temperature | 149°F (65°C) |
| Network (RJ-45) | Yes |
| Load Capacity (VA) | 17.30 kW |
| Load Capacity (Watt) | 17.30 kW |
| TAA Compliant | No |
| PDU Type | Metered-by-Outlet |
| Mounting Orientation | Vertical |
| Product Color | Black |
| Color Family | Black |
| Receptacle Detail | 21 x IEC 60320 C13/C15/C19/C21 |
| Receptacle Detail | 21 x IEC 60320 C13/C15 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Environmental Compliance | Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) |
| Environmental Compliance | China Restriction of Hazardous Substances (China RoHS) |
Marketing Information
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Outlet and PDU level power metering provide power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model's input power cord is IEC-309 60 A 3P+PE and features 21 count C13/C15/C19/C21 combo outlets and 21 count C13/C15 outlets.
- NMC3
- Web
- SNMP
- CLI
Shipping & Dimensions
Similar Products
APC NETSHELTER RACK PDU ADVANCED 11K SERIES, METERED, 2U, 3PH, 208V, 48/60A, 460
APDU11455ME
APC NETSHELTER RACK PDU ADVANCED 11K SERIES, SWITCHED METERED OUTLET, 2U, 3PH, 4
APDU11454SM
APC NETSHELTER RACK PDU ADVANCED 11K SERIES, METERED, 0U, 3PH, 208V, 80/100A, 41
APDU11551ME
APC NETSHELTER SX SERVER RACK GEN 2, 42U, 1991H X 750W X 1070D MM, WITH SIDES, W
AR3150W2
APC NETSHELTER SX, SERVER RACK ENCLOSURE GEN 2, SHOCK PACKAGING, 2500 LBS, BLACK
AR3300SPB2
NETSHELTER SX GEN2 42U 750MM WIDE PERFORATED SPLIT DOORS BLACK - SIMPLE AND TOOL
AR7150B2