Key Features

  • HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Hot-Swap Network Card: Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
  • Star Multi-Linking: PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
  • Temperature/Humidity Monitoring: Primary and Expansion (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
  • IP Access, Security & Communications: Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.
  • Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
  • Per- Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
  • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
  • HDOT (High Density Outlet Technology): The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention, and UL94V-0 flame rating.
  • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 65 °C data center environments.
  • Power Pivot: The 90-degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.
  • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
  • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
SERVER TECHNOLOGY PDUs

SMART EXPANSION PRO2 (36) CONFIGURABLE ALT-BRANCH HDOT OUTLETS, 208V 3BR 30A L6-

Mfr # C2L36TE-2CAF2M99 SKU 5528150

$1,895.75 MSRP $2,240.00 Save 15%

Regular price saves you $344.25 against MSRP.

Available

Contact us to check availability


Product Overview

SMART EXPANSION PRO2 (36) CONFIGURABLE ALT-BRANCH HDOT OUTLETS, 208V 3BR 30A L6-

  • SMART EXPANSION PRO2 (36) CONFIGURABLE ALT-BRANCH HDOT OUTLETS, 208V 3BR 30A L6
  • Server Technology PRO2 Smart 36-Outlets PDU - Monitored - NEMA L6-30P - 18 x IEC 60320 C13, 18 x CX - 230 V AC - Branch Circuit, Circuit Protection, Fuse, Double Pole - Network (RJ-45) - Rack-mountable, Cabinet-mountable, Button Mount
  • Server Technology PRO2 Smart 36-Outlets PDU
  • Monitored - NEMA L6-30P - 18 x IEC 60320 C13, 18 x CX - 230 V AC - Branch Circuit, Circuit Protection, Fuse, Double Pole - Network (RJ-45) - Rack-mountable, Cabinet-mountable, Button Mount

Technical Specifications

Application/Usage IT Equipment
Application/Usage Data Center
Application/Usage Server Rack/Cabinet
Product Type PDU
Input Voltage 230 V AC
Manufacturer Part Number C2L36TE-2CAF2M99
Limited Warranty 2 Year
Output Voltage 208 V AC
Features LED Display
Input Current 30 A
Manufacturer Legrand Group
Product Name PRO2 Smart 36-Outlets PDU
Mount Type Rack-mountable
Mount Type Cabinet-mountable
Mount Type Button Mount
Product Line PRO2
Protection Type Branch Circuit
Protection Type Circuit Protection
Protection Type Fuse
Protection Type Double Pole
Product Series Smart
Brand Name Server Technology
Plug/Connector Type NEMA L6-30P
Height 70"
Width 2.2"
Depth 2.5"
Input Frequency 60 Hz
Phase Three Phase
Receptacle Type IEC 60320 C13
Receptacle Type CX
Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 140°F (60°C)
Minimum Storage Temperature -40°F (-40°C)
Maximum Storage Temperature 185°F (85°C)
Network (RJ-45) Yes
PDU Type Monitored
Power Rating (Watt) 5000 W
Receptacle Detail 18 x IEC 60320 C13
Receptacle Detail 18 x CX
Minimum Operating Humidity 8%
Maximum Operating Humidity 90%

Marketing Information

  • PRO2 Smart 36-Outlets PDU
  • Standard Button Mounts

The Server Technology® PRO2 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart "Primary" PDU can be connected to as many as three (with optional module) PRO2 Smart "Link" PDU to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4 and IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
  • RS-232

Shipping & Dimensions

27
Weight (lbs)
79"
Length
7"
Width
7"
Height

Similar Products