Key Features
- 208V and 120V outlets distribute AC power to connected rack equipment
- 36 C13, 6 C19 and 3 NEMA 5-15/20R outlets split into 6 individually monitored load banks
- Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
- 6 ft. (1.8 m) power cord with NEMA L21-20P input connects to compatible AC source
- Color touchscreen LCD provides vital load and environmental data and network inf
EATON 5.8KW 208/120V 3PH MONITORED PDU - LX INTERFACE, GIGABIT, 45 OUTLETS, L21-
PDU3EVN6L2120
SKU 5363515
UPC 037332206787
Regular price saves you $718.99 against MSRP.
Contact us to check availability
Product Overview
EATON 5.8KW 208/120V 3PH MONITORED PDU - LX INTERFACE, GIGABIT, 45 OUTLETS, L21-
- PDU 3-PHASE 5.8KW VERTICAL MONITORED 0U W/36 IEC C13 6 C19
- Tripp Lite by Eaton PDU 5.8kW 208/120V 3PH Monitored PDU - LX Interface Gigabit 45 Outlets L21-20P Input LCD 1.8 m Cord 0U 1.8 m Height TAA - Monitored - NEMA L21-20P - 36 x IEC 60320 C13, 6 x IEC 60320 C19, 3 x NEMA 5-15/20R - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant
- Tripp Lite by Eaton PDU 5.8kW 208/120V 3PH Monitored PDU - LX Interface Gigabit 45 Outlets L21-20P Input LCD 1.8 m Cord 0U 1.8 m Height TAA
- Monitored - NEMA L21-20P - 36 x IEC 60320 C13, 6 x IEC 60320 C19, 3 x NEMA 5-15/20R - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant
Technical Specifications
| Product Type | PDU |
| Input Voltage | 230 V AC |
| Manufacturer Part Number | PDU3EVN6L2120 |
| Limited Warranty | 2 Year |
| Output Voltage | 120 V AC |
| Output Voltage | 208 V AC |
| Weight (Approximate) | 13.50 lb |
| Input Current | 16 A |
| Manufacturer | Eaton Corporation |
| Product Model | PDU3EVN6L2120 |
| Product Name | PDU3EVN6L2120 45-Outlet PDU |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Brand Name | Eaton |
| Plug/Connector Type | NEMA L21-20P |
| Country of Origin | Taiwan |
| Height | 70" |
| Width | 2.2" |
| Depth | 2.5" |
| Phase | Three Phase |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Type | IEC 60320 C19 |
| Receptacle Type | NEMA 5-15/20R |
| Environmentally Friendly | Yes |
| Network (RJ-45) | Yes |
| TAA Compliant | Yes |
| PDU Type | Monitored |
| Mounting Orientation | Vertical |
| Power Rating (Watt) | 5800 W |
| Receptacle Detail | 36 x IEC 60320 C13 |
| Receptacle Detail | 6 x IEC 60320 C19 |
| Receptacle Detail | 3 x NEMA 5-15/20R |
| Plug/Connector Detail | 1 x NEMA L21-20P |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Marketing Information
- PDU3EVN6L2120 45-Outlet PDU
- Built-in LX Platform Interface
- Configuration Cable
- 42 x Plug-lock Insert Sleeves
- Rack-mounting Hardware
- Spare Mounting Buttons
- PDUMVROTATEBRKT Mounting Bracket Accessory
- Owner's Manual
Features
3-Phase 0U PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.
45 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks-three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
- IPv4
- IPv6
- HTTP
- HTTPS
- SMTP
- SNMPv1
- SNMPv2
- SNMPv3
- telnet
- SSH
- FTP
- DHCP
- NTP
Shipping & Dimensions
Similar Products
MANAGED RACK PDU, 2U, 3PH, L21-30P INPUT, 15FT CORD, 120/208V, 24A, OUTLETS: (24
EMAU19-15
EATON 93PM UPS 480V IN, 208/120V OUT 40KW N+1; ALL COMM CARDS 3 STRINGS BATTS, 3
9AB204J129E20R0
EATON 93PM UPS 480V IN, 208/120V OUT 200KW; ALL COMMUNICATION CARDS, 3 BREAKER M
9AE420J029H20R0
EATON 93PM UPS 480V IN, 208/120V OUT; 50KW 5 STRINGS BATTS, 3 BREAKER MBS
9AA104J325H20R0
EATON 93PM UPS 480V IN, 208/120V OUT 30KW N+1; ALL COMM CARDS, 3 BREAKER MBS
9AC203J029H20R0
COMPUTER POWER CORD, 360 ROTATING RIGHT ANGLED NEMA 5-15P TO C13 - HEAVY-DUTY, 1
P007-010-15RR
