Key Features

  • PDU distributes AC power to multiple servers and balances the load on the servers
  • IEC 60309 3P+G 9Hr 60A plug/connector type for reliable, productive connectivity and optimal power output
  • IEC 60320 C13 receptacle type to ensure maximum dependability and optimal performance
  • 230 V AC input voltage for optimal performance with maximum usability
  • 208 V AC output voltage for optimal performance with maximum feasibility
SERVER TECHNOLOGY PDUs

SMART POPS PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208-240V 3-PH

Mfr # C4T36RA-DQBD2FE1 SKU 14000632

$3,793.19 MSRP $4,482.00 Save 15%

Regular price saves you $688.81 against MSRP.

Available

Contact us to check availability


Product Overview

SMART POPS PRO4X IX PDU, 36 RAMLOCK HDOT OUTLETS (12 C13 + 24 CX), 208-240V 3-PH

  • Smart POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug w/ 3m (9.84 ft) Input Cord
  • Server Technology Smart POPS PRO4X 36-Outlets PDU - IEC 60309 3P+G 9Hr 60A - 12 x IEC 60320 C13, 24 x CX - 230 V AC - Branch Circuit, Circuit Protection, Fuse - Network (RJ-45) - Rack-mountable
  • Server Technology Smart POPS PRO4X 36-Outlets PDU
  • IEC 60309 3P+G 9Hr 60A - 12 x IEC 60320 C13, 24 x CX - 230 V AC - Branch Circuit, Circuit Protection, Fuse - Network (RJ-45) - Rack-mountable

Technical Specifications

Product Type PDU
Input Voltage 230 V AC
Manufacturer Part Number C4T36RA-DQBD2FE1
Limited Warranty 2 Year
Output Voltage 208 V AC
Features Multi-color LCD
Input Current 60 A
Manufacturer Legrand Group
Product Name Smart POPS PRO4X 36-Outlets PDU
Mount Type Rack-mountable
Product Line Smart POPS
Protection Type Branch Circuit
Protection Type Circuit Protection
Protection Type Fuse
Product Series PRO4X
Brand Name Server Technology
Plug/Connector Type IEC 60309 3P+G 9Hr 60A
Height 70"
Width 2.2"
Depth 2.5"
Receptacle Type IEC 60320 C13
Receptacle Type CX
Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 140°F (60°C)
Minimum Storage Temperature -40°F (-40°C)
Maximum Storage Temperature 185°F (85°C)
Network (RJ-45) Yes
Load Capacity (Watt) 17.30 kW
Power Rating (Watt) 17.30 kW
Locking Receptacles RamLock Locking Outlet
Receptacle Detail 12 x IEC 60320 C13
Receptacle Detail 24 x CX
Minimum Operating Humidity 5%
Maximum Operating Humidity 90%

Marketing Information

Key Features | HDOT Cx Outlets

Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.

45 Degree Angled Infeed

The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Multi-Unit Linking & Cascading

Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.

Multi-Color LCD

An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.

Hot Swappable Controller

The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.

Power Quality Measurements

Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.

RGB LED Outlet Indicators

RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.

Waveform Capture

Capture voltage and current waveforms automatically or upon demand.

RamLock Locking Outlets

A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.

Environmental Monitoring

Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.

Per-Inlet Power Sensing

PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

Per-Outlet Power Sensing

POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

Branch Circuit Protection

This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.

  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP

Shipping & Dimensions

31
Weight (lbs)
79"
Length
9"
Width
7"
Height

Similar Products

Free Worldwide shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout

PayPal / MasterCard / Visa