Call us toll free: +1 789 2000

Free worldwide shipping on all orders over $50.00

Key Features

  • HDOT Cx Outlets:
  • Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
  • 45 Degree Angled Infeed:
  • The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
  • Network Monitoring:
  • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
  • Multi-Unit Linking & Cascading:
  • Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
  • Multi-Color LCD:
  • An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
  • Hot Swappable Controller:
  • The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
  • Power Quality Measurements:
  • Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
  • RGB LED Outlet Indicators:
  • RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
  • Waveform Capture:
  • Capture voltage and current waveforms automatically or upon demand.
  • RamLock Locking Outlets:
  • A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
  • Environmental Monitoring:
  • Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
  • Per-Inlet Power Sensing (PIPS®):
  • Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
  • Branch Circuit Protection:
  • This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses.
  • Outlet Control:
  • On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
  • Alternating-Phase Outlets:
  • Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
  • High Temperature Rating:
  • This product has been tested and approved for safe and reliable operation in 60°C data center environments.
  • Flexible Mounting:
  • Includes standard button mounts along with provisions for custom mounting brackets.
  • Color-Coded Options:
  • Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.
SERVER TECHNOLOGY PDUs

380/415V 3PH WYE 30A 60309 3P+N+G 6HR

Mfr # C4W48RA-GPBD2FD3 SKU 9064718

$3,459.74 MSRP $4,088.00 Save 15%

Regular price saves you $628.26 against MSRP.

Available

Contact us to check availability


Product Overview

380/415V 3PH WYE 30A 60309 3P+N+G 6HR

  • LEGRAND SWITCHED PRO4X IX PDU, 48 RAMLOC
  • Server Technology PRO4X 48-Outlets PDU - Switched - IEC 60309 3P+N+G 6Hr 30A - 24 x IEC 60320 C13, 24 x CX - 415 V AC - Branch Circuit, Circuit Breaker, Circuit Protection, Fuse - Network (RJ-45) - Button Mount
  • Server Technology PRO4X 48-Outlets PDU
  • Switched - IEC 60309 3P+N+G 6Hr 30A - 24 x IEC 60320 C13, 24 x CX - 415 V AC - Branch Circuit, Circuit Breaker, Circuit Protection, Fuse - Network (RJ-45) - Button Mount

Technical Specifications

Product Type PDU
Input Voltage 415 V AC
Manufacturer Part Number C4W48RA-GPBD2FD3
Limited Warranty 2 Year
Output Voltage 208 V AC
Output Voltage 230 V AC
Features Multi-color LCD
Input Current 30 A
Manufacturer Legrand Group
Product Name PRO4X 48-Outlets PDU
Mount Type Button Mount
Protection Type Branch Circuit
Protection Type Circuit Breaker
Protection Type Circuit Protection
Protection Type Fuse
Product Series PRO4X
Brand Name Server Technology
Plug/Connector Type IEC 60309 3P+N+G 6Hr 30A
Height 80"
Width 2.2"
Depth 2.5"
Input Frequency 60 Hz
Receptacle Type IEC 60320 C13
Receptacle Type CX
Environmentally Friendly Yes
Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 140°F (60°C)
Minimum Storage Temperature -40°F (-40°C)
Maximum Storage Temperature 185°F (85°C)
Network (RJ-45) Yes
PDU Type Switched
Remote Outlet Switching Yes
Power Rating (Watt) 17.30 kW
Locking Receptacles RamLock Locking Outlet
Receptacle Detail 24 x IEC 60320 C13
Receptacle Detail 24 x CX
Minimum Operating Humidity 5%
Maximum Operating Humidity 90%
Environmental Compliance Restriction of Hazardous Substances (RoHS)

Marketing Information

Server Technology's PRO4X Switched PDUs run on our state-of-the-art Xerus network interface platform and provide remote access to power, PDU status, input and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanism to prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions from Legrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • SNMPv3 (GET, SET, Traps)
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP

Shipping & Dimensions

32
Weight (lbs)
87"
Length
12"
Width
7"
Height
Free Worldwide shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout