Key Features

  • 8 C13 and 2 C19 200-240V outlets distribute AC power to connected equipment
  • Switches from primary to secondary power source in <7 ms for constant operation
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Includes WEBCARDLX with latest version of PADM20 for enhanced remote management
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
  • 2-year limited warranty
EATON PDUs

EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/MONITORED PDU - 8 C13 AN

Mfr # PDUMNH20HVAT1 SKU 6353203 UPC 037332261410

$720.41 MSRP $1,349.00 Save 47%

Regular price saves you $628.59 against MSRP.

Available

Contact us to check availability


Product Overview

EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/MONITORED PDU - 8 C13 AN

  • Tripp Lite (PDUMNH20HVAT1) PDU
  • Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Monitored PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords Network Card 1U TAA - Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant
  • Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Monitored PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords Network Card 1U TAA
  • Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant

Technical Specifications

Product Type PDU
Input Voltage 230 V AC
Manufacturer Part Number PDUMNH20HVAT1
Limited Warranty 2 Year
Output Voltage 200 V AC
Output Voltage 208 V AC
Output Voltage 220 V AC
Output Voltage 230 V AC
Output Voltage 240 V AC
Weight (Approximate) 10.30 lb
Input Current 20 A
Manufacturer Eaton Corporation
Product Model PDUMNH20HVAT1
Product Name PDUMNH20HVAT1 10-Outlets PDU
Mount Type Rack-mountable
Protection Type Circuit Protection
Protection Type Overload Protection
Rack Height 1U
Brand Name Tripp Lite series
Plug/Connector Type IEC 60320 C20
Country of Origin Taiwan
Height 1.7"
Width 17.3"
Depth 14.8"
Phase Single Phase
Receptacle Type IEC 60320 C13
Receptacle Type IEC 60320 C19
Environmentally Friendly Yes
TAA Compliant Yes
PDU Type Auto Transfer Switch
Mounting Orientation Horizontal
Power Rating (Watt) 3800 W
Receptacle Detail 8 x IEC 60320 C13
Receptacle Detail 2 x IEC 60320 C19
Plug/Connector Detail 2 x IEC 60320 C20
Environmental Compliance Restriction of Hazardous Substances (RoHS)

Marketing Information

  • PDUMNH20HVAT1 10-Outlets PDU
  • 2 x Detachable C19 to C20 input cords, 12 ft. (3.7 m)
  • Configuration Cable
  • 10 x Plug-Lock Insert Sleeves
  • Rack-mounting Hardware
  • Owner's Manual

Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time

This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH20HVAT1 features eight C13 and two C19 200-240V outlets for connecting equipment. Dual 12-foot (3.7-meter) power cords with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds

Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Pre-Installed WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control

The HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite's PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.

Mounts into 1U of Rack Space

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack.

TAA-Compliant for GSA Schedule Purchases

The PDUMNH20HVAT1 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

More from the Manufacturer

  • SNMP
  • Telnet
  • SSH
  • HTML5

Shipping & Dimensions

17
Weight (lbs)
23"
Length
20"
Width
5"
Height
Free Worldwide shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout

PayPal / MasterCard / Visa