Key Features

  • 8 C13 and 2 C19 200-240V outlets distribute AC power to connected equipment
  • Switches from primary to secondary power source in <5 ms for constant operation
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Dual 12 ft. power cables connect to separate primary and secondary power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
  • 2-year limited warranty
EATON PDUs

EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/LOCAL METERED PDU - 8 C1

Mfr # PDUMH20HVATS SKU 6353202 UPC 037332261380

$385.04 MSRP $721.00 Save 47%

Regular price saves you $335.96 against MSRP.

Available

Contact us to check availability


Product Overview

EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/LOCAL METERED PDU - 8 C1

  • Tripp Lite (PDUMH20HVATS) PDU
  • Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Local Metered PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords 1U TAA - Metered Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant
  • Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Local Metered PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords 1U TAA
  • Metered Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant

Technical Specifications

Product Type PDU
Input Voltage 230 V AC
Manufacturer Part Number PDUMH20HVATS
Limited Warranty 2 Year
Output Voltage 200 V AC
Output Voltage 208 V AC
Output Voltage 220 V AC
Output Voltage 230 V AC
Output Voltage 240 V AC
Weight (Approximate) 10.30 lb
Input Current 20 A
Manufacturer Eaton Corporation
Product Model PDUMH20HVATS
Product Name PDUMH20HVATS 10-Outlets PDU
Mount Type Rack-mountable
Protection Type Circuit Protection
Protection Type Overload Protection
Rack Height 1U
Brand Name Tripp Lite series
Plug/Connector Type IEC 60320 C20
Country of Origin Taiwan
Height 1.7"
Width 17.3"
Depth 14.8"
Phase Single Phase
Receptacle Type IEC 60320 C13
Receptacle Type IEC 60320 C19
Environmentally Friendly Yes
TAA Compliant Yes
PDU Type Metered Auto Transfer Switch
Mounting Orientation Horizontal
Power Rating (Watt) 3800 W
Receptacle Detail 8 x IEC 60320 C13
Receptacle Detail 2 x IEC 60320 C19
Plug/Connector Detail 2 x IEC 60320 C20
Environmental Compliance Restriction of Hazardous Substances (RoHS)

Marketing Information

  • PDUMH20HVATS 10-Outlets PDU
  • 2 x Detachable C19 to C20 Input Cords, 12 ft. (3.7 m)
  • 10 x Plug-lock Insert Sleeves
  • Rack-mounting Hardware
  • Owner's Manual

Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time

This metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200-240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup.

Switches from Primary to Secondary Power Source in Milliseconds

Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.

Mounts into 1U of Rack Space

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack.

TAA-Compliant for GSA Schedule Purchases

The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Shipping & Dimensions

15.95
Weight (lbs)
23.1"
Length
19.3"
Width
5.2"
Height
Free Worldwide shipping

On all orders above $50

Easy 30 days returns

30 days money back guarantee

International Warranty

Offered in the country of usage

100% Secure Checkout

PayPal / MasterCard / Visa