Key Features
- 8 C13 and 2 C19 200-240V outlets distribute AC power to connected equipment
- Switches from primary to secondary power source in <5 ms for constant operation
- Digital ammeter for on-site real-time load monitoring helps prevent power overloads
- Dual 12 ft. power cables connect to separate primary and secondary power sources
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- 2-year limited warranty
EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/LOCAL METERED PDU - 8 C1
PDUMH20HVATS
SKU 6353202
UPC 037332261380
Regular price saves you $335.96 against MSRP.
Contact us to check availability
Product Overview
EATON TRIPP LITE SERIES 3.8KW 200-240V SINGLE-PHASE ATS/LOCAL METERED PDU - 8 C1
- Tripp Lite (PDUMH20HVATS) PDU
- Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Local Metered PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords 1U TAA - Metered Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant
- Tripp Lite by Eaton PDU 3.8kW 200-240V Single-Phase ATS/Local Metered PDU - 8 C13 and 2 C19 Outlets Dual C20 Inlets 12 ft. Cords 1U TAA
- Metered Auto Transfer Switch - IEC 60320 C20 - 8 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Rack-mountable - TAA Compliant
Technical Specifications
| Product Type | PDU |
| Input Voltage | 230 V AC |
| Manufacturer Part Number | PDUMH20HVATS |
| Limited Warranty | 2 Year |
| Output Voltage | 200 V AC |
| Output Voltage | 208 V AC |
| Output Voltage | 220 V AC |
| Output Voltage | 230 V AC |
| Output Voltage | 240 V AC |
| Weight (Approximate) | 10.30 lb |
| Input Current | 20 A |
| Manufacturer | Eaton Corporation |
| Product Model | PDUMH20HVATS |
| Product Name | PDUMH20HVATS 10-Outlets PDU |
| Mount Type | Rack-mountable |
| Protection Type | Circuit Protection |
| Protection Type | Overload Protection |
| Rack Height | 1U |
| Brand Name | Tripp Lite series |
| Plug/Connector Type | IEC 60320 C20 |
| Country of Origin | Taiwan |
| Height | 1.7" |
| Width | 17.3" |
| Depth | 14.8" |
| Phase | Single Phase |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Type | IEC 60320 C19 |
| Environmentally Friendly | Yes |
| TAA Compliant | Yes |
| PDU Type | Metered Auto Transfer Switch |
| Mounting Orientation | Horizontal |
| Power Rating (Watt) | 3800 W |
| Receptacle Detail | 8 x IEC 60320 C13 |
| Receptacle Detail | 2 x IEC 60320 C19 |
| Plug/Connector Detail | 2 x IEC 60320 C20 |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Marketing Information
- PDUMH20HVATS 10-Outlets PDU
- 2 x Detachable C19 to C20 Input Cords, 12 ft. (3.7 m)
- 10 x Plug-lock Insert Sleeves
- Rack-mounting Hardware
- Owner's Manual
Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200-240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup.
Switches from Primary to Secondary Power Source in Milliseconds
Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Mounts into 1U of Rack Space
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack.
TAA-Compliant for GSA Schedule Purchases
The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Shipping & Dimensions
Similar Products
MANAGED RACK PDU, 2U, 3PH, L21-30P INPUT, 15FT CORD, 120/208V, 24A, OUTLETS: (24
EMAU19-15
COMPUTER POWER CORD, 360 ROTATING RIGHT ANGLED NEMA 5-15P TO C13 - HEAVY-DUTY, 1
P007-010-15RR
EATON END-OF-ROW DOOR SIDE-PANEL EXTENSION FOR RAPIDPOD AISLE CONTAINMENT SYSTEM
NXEORP969
EATON END-OF-ROW DOOR SIDE-PANEL EXTENSION FOR RAPIDPOD AISLE CONTAINMENT SYSTEM
NXEORP9630
EATON END-OF-ROW DOOR SIDE-PANEL EXTENSION FOR RAPIDPOD AISLE CONTAINMENT SYSTEM
NXEORP9627
EATON END-OF-ROW DOOR SIDE-PANEL EXTENSION FOR RAPIDPOD AISLE CONTAINMENT SYSTEM
NXEORP9624