Key Features
- Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
- Switches from primary to secondary power source in <7 ms to maintain constant operation
- Digital ammeter for on-site real-time load monitoring helps prevent power overloads
- Dual 12 ft. cords with NEMA 5-15P inputs connect to separate power sources
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- 2-year limited warranty
EATON TRIPP LITE SERIES 1.44KW 120V SINGLE-PHASE ATS/MONITORED PDU - 8 NEMA 5-15
PDUMNH15AT1
SKU 6335947
UPC 037332261397
Regular price saves you $465.97 against MSRP.
Contact us to check availability
Product Overview
EATON TRIPP LITE SERIES 1.44KW 120V SINGLE-PHASE ATS/MONITORED PDU - 8 NEMA 5-15
- TRIPP 144KW 120V SINGLE-PHASE ATS/MONITO
- Tripp Lite by Eaton PDU 1.44kW 120V Single-Phase ATS/Monitored PDU - 8 NEMA 5-15R Outlets Dual 5-15P Inputs 12 ft. Cords 1U TAA - Metered Auto Transfer Switch - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1U - Horizontal - Rack-mountable, Wall-mountable - TAA Compliant
- Tripp Lite by Eaton PDU 1.44kW 120V Single-Phase ATS/Monitored PDU - 8 NEMA 5-15R Outlets Dual 5-15P Inputs 12 ft. Cords 1U TAA
- Metered Auto Transfer Switch - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1U - Horizontal - Rack-mountable, Wall-mountable - TAA Compliant
Technical Specifications
| Product Type | PDU |
| Input Voltage | 120 V AC |
| Manufacturer Part Number | PDUMNH15AT1 |
| Limited Warranty | 2 Year |
| Output Voltage | 100 V AC |
| Output Voltage | 120 V AC |
| Output Voltage | 127 V AC |
| Weight (Approximate) | 11 lb |
| Input Current | 15 A |
| Manufacturer | Eaton Corporation |
| Product Name | 8-Outlets PDU |
| Mount Type | Rack-mountable |
| Mount Type | Wall-mountable |
| Protection Type | Circuit Protection |
| Rack Height | 1U |
| Brand Name | Tripp Lite series |
| Plug/Connector Type | NEMA 5-15P |
| Country of Origin | Taiwan |
| Height | 1.8" |
| Width | 17.5" |
| Depth | 14.5" |
| Phase | Single Phase |
| Receptacle Type | NEMA 5-15R |
| Environmentally Friendly | Yes |
| TAA Compliant | Yes |
| PDU Type | Metered Auto Transfer Switch |
| Mounting Orientation | Horizontal |
| Power Rating (Watt) | 1520 W |
| Environmental Sensors | Water |
| Environmental Sensors | Temperature |
| Environmental Sensors | Humidity |
| Receptacle Detail | 8 x NEMA 5-15R |
| Plug/Connector Detail | 2 x NEMA 5-15P |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Marketing Information
- 8-Outlets PDU
- Detachable C13 To NEMA 5-15P Secondary Input Cord, 12 Ft. (3.7 m)
- Configuration Cable
- Rack-Mounting Hardware
- Cable Retention Kit
- Owner's Manual
Single-Phase 15A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH15AT1 features eight NEMA 5-15R 120V outlets, which distribute AC power to rack equipment. Dual 12-foot (3.7-meter) power cords with NEMA 5-15P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.
Switches from Primary to Secondary Power Source in Milliseconds
Automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2-7 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite's PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
Digital Load Meter Helps Prevent Potentially Expensive Overloads
A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.
TAA-Compliant for GSA Schedule Purchases
The PDUMNH15AT1 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems.
Shipping & Dimensions
Similar Products
MANAGED RACK PDU, 2U, 3PH, L21-30P INPUT, 15FT CORD, 120/208V, 24A, OUTLETS: (24
EMAU19-15
COMPUTER POWER CORD, 360 ROTATING RIGHT ANGLED NEMA 5-15P TO C13 - HEAVY-DUTY, 1
P007-010-15RR
EATON 93PM UPS 480V IN, 208/120V OUT 40KW N+1; ALL COMM CARDS 3 STRINGS BATTS, 3
9AB204J129E20R0
EATON 93PM UPS 480V IN, 208/120V OUT 200KW; ALL COMMUNICATION CARDS, 3 BREAKER M
9AE420J029H20R0
EATON 93PM UPS 480V IN, 208/120V OUT; 50KW 5 STRINGS BATTS, 3 BREAKER MBS
9AA104J325H20R0
EATON 93PM UPS 480V IN, 208/120V OUT 30KW N+1; ALL COMM CARDS, 3 BREAKER MBS
9AC203J029H20R0